You are here:

102GA, 102GH

Pilot operated check valves

Technical features

Medium

Compressed air

Operation

Essentially a pilot operated check valve, a blocking fitting allows air flow in both directions if a pilot pressure is applied to port 12. When pressure to the pilot port is removed, flow occurs in one direction only, due to an integral non-return valve. When used in pairs, blocking fittings can control an actuator to give safe operation in the event of an electrical problem, air failure or tube breakage. In order to provide a ‘safe system’, all possible conditions need to be considered in the event of an emergency.

Operating pressure

1… 10 bar (14 … 145 psi)

Tube size

4, 6, 8, 10 mm

Thread size

G1/8, G1/4, G3/8, G1/2

Tube types

PA 11 or 12, PU and other plasticised or unplasticised tubing

Pilot port

M5 (102GA), G1/8 (102GH)

Ambient/Media temperature

-20°C … +80°C (-4 … +176°F)
Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F).

Materials

Body and banjo bolt: nickel plated brass
Washer: NBR and PUR

Alternative variants

NPTF-ports on request