You are here:

96000 Series

Direct solenoid actuated poppet valves

Technical features

Medium

For neutral gaseous and liquid fluids (with contaminated fluids, upstream installation of a dirt trap is recommended)

Operation

Direct solenoid operated poppet valve

Operating pressure

0 … 18 bar (0 … 261 psi)

Orifice

2 … 5 mm

Port size

G1/4, 1/4 NPT

Flow direction

Depending on solenoid system fixed or optional

Mounting position

Optional, preferably with solenoid on top

Ambient/Media temperature

NBR:
-25 … +80°C (-13 … +176°F)
FPM:
-10…+120°C (+14 … +248°F)
Water +95°C (+203°F)
EDPM:
-40… +140°C (-40 … +284°F)
FFPM:
-10….+140°C (+14 … +284°F)
Depending on solenoid system and seal materials.
Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F).

Material

Housing: brass 2.0401 (Ms 58)
Seals: NBR, others see option selector
Inner parts:
stainless steel 1.4104 (430 F)
brass 2.0401 (Ms 58)

Flow conversion

Cv US Gallon/min (water) = l/min (air) x 0,001
Kv m³/h (water) = l/min (air) x 0,000906