P64S – Olympian Plus plug-in system

Soft start monitored dump valves

Technical features

Medium

Compressed air only

Operating pressure

3 bar (43 psi) minimum
10 bar (145 psi) maximum

Snap pressure

Full flow when downstream pressure reaches 35 … 60% of inlet pressure

Charge time

For 2 litre downstream volume and 6,3 bar (90 psi) inlet pressure
0,2 sec. minimum
75 sec. maximum

Port sizes

1/4”, 3/8”, 1/2” or 3/4”

Exhaust port

G1/2 with ISO G main ports
1/2“ PTF with PTF main ports

Gauge Ports

Rc1/8

Ambient/Media temperature

0 … +50°C (+32 … +122°F)
Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F).

Materials

Body: Zinc alloy
Intermediate body: Aluminium
Filter discs: Sintered plastic
Internal components: Brass; steel or stainless steel
Top plate: Aluminium
Exhaust Bonnet: Zinc alloy
Yoke: Zinc alloy
Elastomers: NBR