You are here:

P72F – EXCELON® Modular System

Soft start/dump valves

Technical features

Product Type

FRL Control Valves

Medium

Compressed air only

Maximum operating pressure

17 bar (250 psi) pilot actuated
10 bar (145 psi) solenoid actuated

Minimum operating pressure

3 bar (44 psi)

Snap pressure

Full flow when downstream pressure reaches 50 – 80% of inlet pressure

Port size

G1/4, G3/8, 1/4” or 3/8” PTF

Air pilot port

M5 with ISO G main ports
10-32 UNF with PTF main ports

Exhaust port

Rc1/4 with ISO G main ports
1/4 PTF with PTF main ports

Charge time

For 2 litre downstream volume and 6,3 bar (90 psi) inlet pressure
0,8 sec. minimum
99 sec. maximum

Flow

Operating pressure: 6,3 bar (91psi) Δp: 0,5 bar (7 psi)
P1 to P2 = Cv 1,59
P2 to P3 = Cv 1,72

Ambient/Media temperature

Solenoid actuated:
-20° … +50°C (-4° … +122°F)
Pilot actuated:
-20° … +65°C (-4° … +149°F)
Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F).

Materials

Body: Zinc alloy
Elastomers: Synthetic materials
Internal components: Brass/steel